Aube TH115 Programmable Thermostat Manual

Before you start

Programmable thermostat

Aube TH115 Thermostat Barcode

Read before installing

Models

  • TH115-A-120S/U
  • TH115-A-240D-B/U
  • TH115-A-240S-B/U
  • TH115-AF-024T/U
  • TH115-AF-120S/U
  • TH115-AF-12VDC/U
  • TH115-AF-240S/U

Read the entire document

CAUTION:

  • Installation must be carried out by a certified electrician and must comply with national and local electrical codes.
  • To prevent severe shock or electrocution, always cut the power at the service panel before working with wiring.
  • Use this thermostat for resistive loads only.
  • Do NOT install the thermostat in an area where it can be exposed to water or rain.
  • Avoid locations where there are air drafts (top of the staircase, air outlet), dead air spots (behind a door), direct sunlight or concealed chimney or stove pipes (except for floor heating systems).
  • For a new installation, choose a location about 1.5 m (5 ft.) above the floor.
  • Install the thermostat on an inside wall facing the heating system (except for floor heating systems).
  • Install the thermostat onto an electrical box.
  • Use special CO/ALR solderless connectors if you connect the thermostat to aluminum wires.
  • Keep the thermostat’s top and bottom air vents (openings) clean and unobstructed at all times..

About your thermostat

The TH115 programmable thermostat has three temperature control modes:

A mode: controls the ambient air temperature
F mode: controls the floor temperature using an external temperature sensor
AF mode: controls the ambient air temperature maintains the floor temperature within desired limits using an external temperature sensor

Supplied Parts

  • One (1) thermostat
  • Two (2) mounting screws
  • One (1) floor sensor *
  • One (1) flat-tip screwdriver *
  • Four (4) solderless connectors for copper wires

Select models only; required for floor heating applications only.

Controls

Aube TH115 Thermostat Control

*Place at Off/Standby to cut power to the heater (e.g., in the summer). This will not affect the time and temperature settings.
**When the backlight button or either of theaube TH115-A-120S U Single Pole Programmable Thermostat - icon 12 buttons is pressed, the display illuminates for 12 seconds.

Display

Aube TH115 Thermostat Display

* The thermostat normally displays the actual (measured) temperature. To view the setpoint temperature, briefly press either of theaube TH115-A-120S U Single Pole Programmable Thermostat - icon 12 buttons. The setpoint will appear for 5 seconds. To change the setpoint temperature, press one of the aube TH115-A-120S U Single Pole Programmable Thermostat - icon 12buttons until the desired temperature is displayed. To scroll faster, press and hold the button.

Installing the thermostat

  1. Turn the heating system off at the main electrical panel.
  2. Loosen the bottom screw and remove the thermostat faceplate from its wallplate. (The screw cannot be completely  removed.)
  3. Connect the thermostat to the load and to the power supply (see page 7).
  4. If the thermostat will be used in F or AF Mode (see page 9), connect the floor sensor (see page 8).
    WARNING: For floor heating applications, you must install a separate ground protection device at the main electrical panel or use a thermostat with a built-in ground protection device.
  5. If you wish to connect a remote control device, see page 8.
  6. Install the wall plate to the electrical box using the provided screws.
  7. Set the configuration switches on the back of the faceplate (see page 9).
  8. Install the faceplate back on the wall plate and tighten the screw.
  9. Apply power to the heating system at the main electrical panel.

Wiring diagram

NOTE: Connect the wires using the provided solderless connectors for copper wires.

  1. Insert the floor sensor cable through one of the two openings on the wall plate and connect the sensor wires to terminals 3 and 4 (no polarity).
    • The sensor wires must not come in contact with the electrical wires and must be routed outside the electrical box and follow the wall down to the floor.
    • Position the sensor cable such that it does not come in contact with the floor heating wires. The sensor must be centered between two-floor heating wires for the best temperature control.
    • Do NOT staple the sensor head (the plastic end) to the floor. Doing so might damage the sensor. Any damage might not be noticeable during testing but can become apparent several days later.
  2. If you wish to connect a remote control device (see page 17), insert the wires (use 18- to 22-gauge flexible wires) through  one of the two openings on the wallplate and connect them to terminals 1 and 2 (no polarity).

Aube TH115 WIring Diagram

Connecting the floor sensor / remote control

# Configurations Up Down
1 Display format °F / 12 h °C / 24 h
2 Early Start¹ Enable Disable
3 Temperature control mode² FA AF

Aube TH115 Wiring

  1. Early Start is used in Automatic mode only. When Early Start is enabled (on), the thermostat determines when to start heating so the Comfort temperature is attained at the beginning of periods 1 and 3. When Early Start is disabled (off),  heating starts only at the beginning of periods 1 and 3; thus there is a delay before the Comfort temperature is reached.
  2. See page 3. To select the F Mode, place the switch in the F position. To select the AF Mode, place the switch in the AF  position and ensure that the temperature sensor is connected to the thermostat. To select the A Mode, place the switch in the AF position and ensure that the remote temperature sensor is NOT connected to the thermostat.

Time and day

To set the clock and the day:

  1. Press the Hour button to set the hour.
  2. Press the Min button to set the minutes.
  3. Press the Day button to set the day.
  4. Press the Mode/Ret button to return the thermostat to a normal display.

NOTE: The thermostat will automatically return to normal display if no button is pressed for 60 seconds.

Daylight Saving Time

When the Daylight Saving Time function is enabled (On), the thermostat automatically switches to Daylight Saving Time on the second Sunday of March and to normal time on the first Sunday of November.

NOTE: The Daylight Saving Time function is disabled (default setting) when the clock loses its setting.
To set the Daylight Saving Time function and to set the date:

  1. Press the Day button (3 seconds) until DLS appears on the screen.
  2. Press either of theaube TH115-A-120S U Single Pole Programmable Thermostat - icon 12 buttons to toggle between On (enabled) and Off (disabled).
  3. Press the Day button briefly. The year setting is displayed.
  4. Press either of theaube TH115-A-120S U Single Pole Programmable Thermostat - icon 12 buttons to set the current year.
  5. Press the Day button briefly. The month setting is displayed.
  6. Press either of theaube TH115-A-120S U Single Pole Programmable Thermostat - icon 12 buttons to set the current month.
  7. Press the Day button briefly. The date setting is displayed.
  8. Press either of the aube TH115-A-120S U Single Pole Programmable Thermostat - icon 12buttons to set the current date.
  9. Press the Mode/Ret button to return the thermostat to a normal display.

NOTE: The thermostat will automatically return to normal display if no button is pressed for 60 seconds.

Floor temperature limits (AF mode only)

WARNING: To avoid damaging your floor, follow your floor supplier’s recommendations regarding floor temperature limits.
The minimum and maximum floor temperature limits are 5.0°C (41°F) and 28.0°C (82°F) by default. To modify these limits, proceed as follows:

  1. Switch the thermostat Off.
  2. Press and hold theaube TH115-A-120S U Single Pole Programmable Thermostat - icon button.
  3. Switch the thermostat back to On.
  4. Release the aube TH115-A-120S U Single Pole Programmable Thermostat - iconbutton when the minimum temperature limit (FL: LO) appears.
  5. Set the minimum temperature limit using theaube TH115-A-120S U Single Pole Programmable Thermostat - icon 12 buttons.
  6. Press theaube TH115-A-120S U Single Pole Programmable Thermostat - icon button to display the maximum temperature limit (FL: HI).
  7. Set the maximum temperature limit using theaube TH115-A-120S U Single Pole Programmable Thermostat - icon 12 buttons.
  8. Press Mode/Ret to return the thermostat to the normal display.

The thermostat has 3 preset temperatures. Their default settings are shown in the following table.

Preset temperature

Intended use

Icon

A/AF modes

F mode

Comfort

When at home

aube TH115-A-120S U Single Pole Programmable Thermostat - icon

21.0°C (70°F)

28.0°C (82°F)

Economy

When asleep or away from home

aube TH115-A-120S U Single Pole Programmable Thermostat - icon 2

17.0°C (63°F)

20.0°C (68°F)

Vacation

During prolonged absence

aube TH115-A-120S U Single Pole Programmable Thermostat - icon 3

10.0°C (50°F)

10.0°C (50°F)

To use a preset temperature:
Briefly press the appropriate preset temperature button (, or ). The preset temperature will become the current setpoint and its icon will appear on the screen.

To modify a preset temperature:

  1. Press one of the aube TH115-A-120S U Single Pole Programmable Thermostat - icon 12buttons to display the desired temperature.
  2. Press and hold the appropriate preset temperature button (aube TH115-A-120S U Single Pole Programmable Thermostat - icon,aube TH115-A-120S U Single Pole Programmable Thermostat - icon 2or aube TH115-A-120S U Single Pole Programmable Thermostat - icon 3 ) until its icon is displayed.

Default schedule

The schedule consists of 4 periods per day, which represents a typical work day. The Comfort ( aube TH115-A-120S U Single Pole Programmable Thermostat - icon) preset temperature is automatically used in Periods 1 and 3 and the Economy (aube TH115-A-120S U Single Pole Programmable Thermostat - icon 2 ) preset temperature in Periods 2 and 4. You can program the thermostat to skip (cancel) the periods that do not apply to your situation. For example, you can skip periods 2 and 3 for the weekend.
NOTE: If you wish to use only 2 periods, use the following combinations: “1 and 4” or “2 and 3”. Early Start (see page 9) will not work with any other combinations. You can have a different program every day; i.e., each period can start at a different time every day. The thermostat has been programmed with the following schedule.

Period

Description

Setting

MO

TU

WE

TH

FR

SA

SU

aube TH115-A-120S U Single Pole Programmable Thermostat - icon 3

Wake

Comfort aube TH115-A-120S U Single Pole Programmable Thermostat - icon

6:00 AM

6:00 AM

6:00 AM

6:00 AM

6:00 AM

6:00 AM

6:00 AM

aube TH115-A-120S U Single Pole Programmable Thermostat - icon 4

Leave

Economyaube TH115-A-120S U Single Pole Programmable Thermostat - icon 2

8:30 AM

8:30 AM

8:30 AM

8:30 AM

8:30 AM

–:–

–:–

aube TH115-A-120S U Single Pole Programmable Thermostat - icon 5

Return

Comfort aube TH115-A-120S U Single Pole Programmable Thermostat - icon

5:00 PM

5:00 PM

5:00 PM

5:00 PM

5:00 PM

–:–

–:–

aube TH115-A-120S U Single Pole Programmable Thermostat - icon 6

Sleep

Economyaube TH115-A-120S U Single Pole Programmable Thermostat - icon 2

11:00 PM

11:00 PM

11:00 PM

11:00 PM

11:00 PM

11:00 PM

11:00 PM

Modifying the schedule

  1. Press PGM. Period 1 for Monday is displayed.
  2. To program another period, press Pgm to display that period.
  3. To program another day, press Day to display that day (hold for 3 seconds to select the entire week).
  4. Press Hour and Min to set the period start time or press Clear to skip (cancel) the period (–:– will be displayed).
  5. Repeat steps 2 to 4 to program another period.
  6. Press Mode/Ret to return the thermostat to the normal display.

NOTE: The thermostat will automatically return to normal display if no button is pressed for 60 seconds.

Running the schedule (Automatic mode)

In Automatic mode, the thermostat follows the programmed schedule (see page 14). To place the thermostat in this mode, press  Mode/Ret until is displayed.

Temporary override of schedule

If you modify the setpoint temperature (by pressing theaube TH115-A-120S U Single Pole Programmable Thermostat - icon 12,aube TH115-A-120S U Single Pole Programmable Thermostat - icon oraube TH115-A-120S U Single Pole Programmable Thermostat - icon 2 button) when the thermostat is in Automatic mode, the new emperature will be used until the beginning of the next period. aube TH115-A-120S U Single Pole Programmable Thermostat - icon 312 flashes during the temporary override. You can cancel the temporary override by pressing Mode/Ret.

Error Messages

aube TH115-A-120S U Single Pole Programmable Thermostat - icon 22 The measured temperature is below the display range. Heating is activated.

 The measured temperature is above the display range. The heating is deactivated.

aube TH115-A-120S U Single Pole Programmable Thermostat - icon 24. Verify the thermostat connection and sensor connection.

Technical Specifications

Model

Supply

Maximum current

Maximum wattage

Wiring

120S

120 VAC, 50Hz/60Hz

16.7 A

2000 W

4 wires / single pole

240S

240 VAC, 50Hz/60Hz
208 VAC, 50Hz/60Hz

16.7 A

4000 W
3470 W

4 wires / single pole

240D

240 VAC, 50Hz/60Hz
208 VAC, 50Hz/60Hz

15 A

3600 W
3120 W

4 wires / double pole

  • Display range: 0°C to 70.0°C (32°F to 158°F)
  • Ambient setpoint range (A/AF modes): 5.0°C to 30.0°C (40°F – 86°F)
  • Floor setpoint range (F mode): 5.0°C to 40.0°C (40°F – 104°F)
  • Floor limit range (AF mode): 5.0°C to 40.0°C (40°F – 104°F)
  • Resolution: 0.5°C (1°F)
  • Heating cycle length: 15 minutes
  • Data protection: In the event of a power failure, most settings are saved. However, the time and Daylight Saving Time must be  set if the power failure lasts more than 6 hours. The thermostat will return to the mode that was active prior to the power failure.