Aube TH114 Non-Programmable Thermostat User Manual
Description
Aube's TH114 non-programmable thermostat can be used to control the ambient air temperature or floor temperature. You can select among the following temperature control modes:
A mode:
- controls and displays the ambient air temperature
F mode:
- controls and displays the floor temperature using an external temperature sensor
AF mode:
- controls and displays the ambient air temperature
- maintains the floor temperature within desired limits using an external temperature sensor
- 1 The thermostat displays the percentage use of heating required to maintain the desired temperature. For example, is displayed when heating is at 40 percent.
- 2 GFI appears when the ground fault protection has triggered.
- 3 Place the thermostat in Standby to cut power to the heater when it is not in use (e.g. in summer).
- 4 To reset the ground fault protection, switch the thermostat to Standby and back to On.
Configuration
The configuration switches are located at the back of the control module (faceplate).
Temperature Display (S1)
The S1 switch is used to select between °C (default) and °F.
Temperature Control Mode
(S2) This switch is used to select the temperature control mode.
F: To select the F mode
AF: To select the A or AF mode (default)
Installation
- Refer to the installation instructions of the power base.
- Insert the tabs at the top of the control module in the slots at the top of the power base.
- Secure the control module using the captive screw underneath the base.
NOTE: Keep the thermostat's air vents clean and unobstructed at all times.
Power-up
Upon power-up, the thermostat undergoes a series of tests before displaying the actual (measured) temperature.
Error Messages
- The measured temperature is below the thermostat’s display range. Heating is activated.
- The measured temperature is above the thermostat’s display range. Heating is deactivated.
- Verify the thermostat and sensor connections.
Backlight
The display illuminates for 5 seconds when the backlight button is pressed. When either of the UP or DOWN buttons is pressed, the display illuminates for 10 seconds. The setpoint temperature appears for 5 seconds, then the actual (measured) temperature is displayed.
Temperature Display and Setting
Setpoint Temperature
The thermostat normally displays the actual (measured) temperature. To view the setpoint, press once on one of the UP or DOWN buttons. The setpoint is displayed for 5 seconds. To change the setpoint, press one of the UP or DOWN buttons until the desired temperature is displayed. To scroll faster, press and hold the button.
Floor Temperature Limits (AF mode only)
The thermostat generally turns heating On or Off to control the ambient temperature. However, if the floor temperature drops below the set minimum floor temperature limit or rises above the maximum limit, the thermostat will turn heating On or Off respectively, regardless of the ambient temperature, to maintain the floor temperature within the desired limits. The minimum and maximum floor temperature limits are factory-set at 10 °C (50 °F) and 28 °C (82 °F) respectively. To modify the limits, proceed as follows:
- Switch the thermostat to Standby.
- While pressing any button, switch the thermostat back to On to access the floor temperature limit settings.
- Press the Backlight button briefly to switch between minimum and maximum floor temperature settings.
- Press the UP or DOWN buttons to set the desired limit.
- Press the Backlight button for 3 seconds to save your modifications. After the data are saved, the thermostat displays the actual ambient temperature or “– –”.
Note: Your modifications are also saved if no button is pressed for 60 seconds.
Unoccupied Mode
Note: This feature is available only if the thermostat is mounted on a power base that has the unoccupied mode input (ECONO). The thermostat can be connected to any other remote control device equipped with a dry contact. When the contact closes, the Unoccupied mode is activated and the Unoccupied mode icon is displayed. In this mode, the thermostat lowers its setpoint by 3.5°C (7°F) and all temperature adjustments are blocked except for temporary bypass.
Temporary Bypass
To temporarily bypass the Unoccupied mode, press the backlight button. During the bypass, the Unoccupied mode icon flashes. The bypass is automatically cancelled after 2 hours or if the backlight button is pressed again.
Technical Specifications
- Power supply: Refer to the power base installation instructions.
- Setpoint range
- F mode: 5 °C to 40 °C (40 °F to 104 °F)
- A/AF mode: 5 °C to 30 °C (40 °F to 86 °F) Floor limit range (AF mode): 5 °C to 40 °C (40 °F - 104 °F)
- Display range -
- F mode: 0 °C to 60 °C (32 °F to 140 °F)
- AF mode: 0 °C to 50 °C (32 °F to 122 °F)
- Resolution: ± 0.5 °C (1.0 °F) Duty cycle: Refer to the power base installation instructions.
- Storage: -20 °C to 50 °C (-4 °F - 120 °F)