Honeywell RLV4300 5-2 Programmable Thermostat Manual

Honeywell RLV4300 Specifications

Supply: 120/240 VAC, 60 Hz
Minimum load: 1.25 A (resistive only)
150 W @ 120 V AC
300 W @ 240 V AC
Maximum load: 12.5 A (resistive only)
1500 W @ 120 V AC
3000 W @ 240 V AC
Display range: 0 °C to 50.0 °C (32 °F to 99 °F)
Setpoint range: 5.0 °C to 27.0 °C (41 °F to 81 °F)
Resolution: 0.5 °C (1 °F)
Storage temperature: -20.0 °C to 50.0 °C (-4 °F to 120 °F)

Application

This thermostat is designed to control an electric heating system such as a baseboard heater, a radiant ceiling, a convector or a fan-forced heater. The thermostat CANNOT be used with:

  • a resistive load under 1.25 A
  • a resistive load over 12.5 A
  • a system driven by a contactor or a relay (inductive load)
  • a central heating system.

Installation guidelines

TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK.

  •  All cables and connections must comply with local electrical codes.
  • This thermostat has tinned copper wires for line and load connec- tions. Special CO/ALR solderless connectors must be used if these wires will be connected to aluminium conductors.
  • Install the thermostat onto an electrical box.
  • Install the thermostat about 1.5 m (5 feet) high, on an inside wall facing the heater.
  • Avoid locations where there are air drafts (such as the top of a staircase or an air outlet), dead air spots (such as behind a door), or direct sunlight.
  • Do not install the thermostat on a wall that conceals chimney or stove pipes.
  • The thermostat wires are not polarized; either wire can be con- nected to the load or to the power supply. 

Clock and day setting

The clock must be set when Time appears on the screen.

  1. Pull the cover down.
  2. Press the Day button to set the day.
  3. Use the Hour and Min buttons to set the clock.
  4. Press the Ret button to exit.

Temperature display and setting

The thermostat normally displays the room (measured) temperature.

  1. To display the set temperature (setpoint), press the Up or Down button once.
  2. The setpoint temperature will remain on the screen for 5 seconds.
  3. To change the setpoint temperature, press the Up or Down button repeatedly until the desired temperature is displayed.
  4. The screen is backlit for 12 seconds when any button is pressed.

Automatic mode

To place the thermostat in Automatic mode, press the Mode button until Auto appears on the screen. The current period number also appears. In this mode, the thermostat follows the programmed schedule. You can program up to 4 periods in a day. You can set 2 different programs: one for the weekdays (Monday to Friday) and another one for the weekend (Saturday and Sunday). 

Temporary Override

You can temporarily override the current temperature using the Up or Down button. The new setpoint will be used until the end of the current period. During the override, Auto flashes on the screen.

Automatic mode (continued)

To modify the schedule:

  1. Press the Mode button until Auto appears on the screen.
  2. Press the Pgm button. Period 1 of the weekday (Monday to Friday) program is displayed.
  3. To display another period, press the Pgm button.
  4. To toggle between the weekday (Mon to Fri) program and the weekend (Sat & Sun) program, press the Day button.
  5. Press the Hour and Min buttons to set the start time of the displayed period. NOTE: To cancel the period, press the Mode button. The thermostat will display --:--. During operation, the thermostat will skip over that period.
  6. Press the Up or Down button to set the temperature of the displayed period.
  7. Repeat steps 3 through 6 to set another period.
  8. Press the Ret button to end programming.