Honeywell CT3500/CT3595 THERMOSTAT Manual
Replacing a Clock Thermostat that has C or C1 Clock Terminals
If you are replacing a Honeywell Chronotherm® Thermostat, you may find one or two wires going to the C or C1 clock terminals on the Chronotherm wiring wallplate. Do not allow them to touch, or you can damage the transformer. Disconnect the wires and wrap them separately using electrical tape. Do not wrap them together. Place the wires where they will not interfere with the operation of the new thermostat. Record the colors and terminal designation labels of the remaining wires.
Replacing a Thermostat that has Six or More Wires
If there are six or more wires (excluding clock wires attached to terminals), you probably have a variation of a multistage heat pump or other multistage system. This thermostat is not compatible with multistage systems, so return the product to the place of purchase. For information about which programmable thermostats will work with you system.
Honeywell CT3500/CT3595 Compatibility
System Type |
Compatibility with CT3500/CT3595 |
Gas — Standing Pilot |
Yes |
Gas — Electronic Ignition |
Yes |
Gas-fired Boilers |
Yesa |
Gas — 750 Millivolt Heat onlyb |
Yes |
Oil-Fired Boilers |
Yesa |
Oil-Fired Furnace |
Yes |
Electric Furnace |
Yes |
Electric Air Conditioning |
Yes |
Baseboard Electric (120/240 line volt)c |
No |
Single Stage Heat Pump |
Yes |
Multistage Heat Pumps/Multistage Equipment |
No |