Emerson 1F83H-21NP User Manual
Emerson 1F83H-21NP SPECIFICATIONS
Electrical Rating:
- Battery Power 20 to 30 VAC, NEC Class II, 50/60 Hz
- Input-Hardwire 20 to 30 VAC, NEC Class II, 50/60 Hz
- Terminal Load 1.5 A per terminal, 2.5A maximum all terminals combined
- Setpoint Range 45° to 99° F (7° to 37° C)
Rated Differentials (@ 6°F/ Hr): Fast Med Slow
- Heat Pump (Heat) 0.9°F 1.2°F 1.7°F
- Heat Pump (Cool) 0.9°F 1.2°F 1.7°F
- Auxiliary Heat 0.5°F 0.75°F 1.9°F
- Operating Ambient 32°F to +105°F (0° to +41°C)
- Display Temperature Range 32°F to +99°F (0 to 37°C)
- Operating Humidity 90% non-condensing maximum
- Shipping Temperature Range -20°F to + 150°F (-29° to +65°C)
- Thermostat Dimensions 3-3/4” H x 6” W x 1-1/8” D
TEST EQUIPMENT
Turn on power to the system.
Fan Operation
If your system does not have a G terminal connection, skip to Heating System.
- Move fan switch to On position. The blower should begin to operate.
- Move fan switch to Auto position. The blower should stop immediately.
Heating System
- Move System Switch to Heat position. If the auxiliary heating system has a standing pilot, be sure to light it.
- Press to adjust thermostat setting to 1° above room temperature. The heat pump system should begin to operate and the thermostat will indicate Heat On.
- Press to adjust thermostat setting to 3° above room temperature. The auxiliary heat should begin to operate and the thermostat will indicate Heat On Auxiliary.
- Press to adjust thermostat setting 1° below room temperature. The heating system should stop operating and the thermostat should indicate Heat.
Auxiliary System
- Move System Switch to Aux position. If the auxiliary heating system has a standing pilot, be sure to light it.
- Press to adjust thermostat setting to 1° above room temperature. The auxiliary heating system should begin to operate and the thermostat will indicate Heat On Auxiliary.
- Press to adjust thermostat setting 1° below room temperature. The auxiliary heating system should stop operating and the thermostat should indicate Heat Auxiliary.
Cooling System
- Move System Switch to Cool position.
- Press to adjust thermostat setting 1° below room temperature. The blower should come on immediately on high speed, followed by cold air circulation. The thermostat will indicate Cool On. There can be up to a 5 minute delay. (see INSTALLER MENU, item 50)
- Press to adjust thermostat setting to 1° above room temperature. The cooling system should stop operating and the thermostat will indicate Cool.
Readmore and Download Emerson 1F83H-21NP User Manual PDF