Dometic 3314082.000 Comfort Control Center 2 Thermostat Manual

Dometic Comfort Control Center 2 Thermostat Quick Start-Up

The basic steps for operating your Air Conditioner & Heat Pump (herein after referred to as the “unit”), are described in this User’s Guide. For more detailed information on modes of operation and special features refer to the Operating Instructions Manual.

Dometic 3314082.000 Reference Button

Dometic 3314082.000 Special Features

  • Auto Fan
  • Stage Select (Two air conditioners/heat pumps or models equipped with two compressors)
  • Programs 1 & 2
  • Auxiliary Heat (heat pump models only)
  • Load Shed
  • Automatic Generator Start (optional) See Operating Instructions Manual for more information on special feature.

LCD Error Code

When the system determines that one of the faults listed below has occurred an error code will be displayed in the LCD for the zone in which the error occurred. During normal operation, a blinking zone number indicates a fault has occurred. The error code is displayed in place of the temperature set-point.

Error Code:

  • E1 Loss of communication between the CCC 2 thermostat and all system power module boards. System will shut down.
  • E1 Loss of communication between the CCC 2 thermostat and an individual system power module board. The LED will display error code E1 and the zone number that lost communication. Any additional zones that lose communication will blink in addition to the current zone.
  • E2 Open circuit or out-of-range Indoor Temperature Sensor. All heat and cool operation will be locked out. Manual fan operation can continue.
  • E3 Shorted Indoor Temperature Sensor. All heat and cool operation will be locked out. Manual fan operation can continue.
  • E4 Open circuit or out of range Outdoor Temperature Sensor (select models). Heat pump operation will be locked out. Air conditioner, furnace, heat strip, and fan operation can continue to operate.
  • E5 Open circuit or out of range Freeze Sensor. Air conditioner operation will be locked out. Heat pump, furnace, heat strip, and fan operation can continue to operate but displays the last temperature set-point.
  • E7 Loss of 120 VAC power to all power module boards on the system. The system will shut down.
  • E8 Invalid zone configuration. The heat pump and heat strip DIP switches are both set to the ON position in one zone. Heat pump, heat strip and air conditioner operation will be locked out in the affected zone.
  • E9 Invalid zone configuration. The dehumidifier DIP switch and either the heat pump or heat strip DIP switches are set to the ON position in one zone. Heat pump, heat strip, and air conditioner operation will be locked out in the affected zone.